<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15602</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: plate not found, check picker suction cup adjustment
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
A plate was not found by the picker.  This is most likely due to an
obstruction (the picker suction cups against the plate box, for instance)
preventing the picker from reaching the plates.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Adjust the picker suction cups by doing a 'config picker'.
</text></DescriptionText>
</OperatorAction>
<Cause>
This is most likely due to an obstruction (the picker suction cups
against the plate box, for instance) preventing the picker from
reaching the plates.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:15 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/computer_to_plate/vlf_platesetter/content/troubleshooting/15602.htm</LinkAddress><LinkTitle>Other: Troubleshooting information</LinkTitle></Link>
</Links>
</Error>